HCPAnalysis & Measurement
Half-Cell Potential Meter
Half-cell potential mapping measures the electrical potential between embedded reinforcement and a copper/copper sulphate reference electrode on the concrete surface. More negative readings indicate higher corrosion probability.
Testing is performed on a systematic grid (typically 300mm spacing), producing contour maps of corrosion probability across the structure. ASTM C876 provides standard interpretation criteria.
Half-cell mapping consistently shows that the spatial extent of active corrosion is less than visual assessment suggests, enabling targeted and cost-effective remediation.
Applications
- 01Corrosion probability assessment
- 02Remediation boundary delineation
- 03Post-repair corrosion state verification
- 04Marine and coastal structure assessment
- 05Long-term condition monitoring